pzd pipettes

PZD Pipettes

Description / Use

  • SLM PZD Pipettes are used to cut an opening on the zona pellucida of an oocyte mechanically to enable assisted hatching and/or embryo biopsy.
  • The pipette is designed with a very sharp tip and a strong taper section for easy control and precision manipulation.
  • They are supplied with 0°-45° tip angle and a tip to elbow length of 0.55mm.
Catalogue No. Description Tip Angle Degree
SPD-30 Solid sharp tip 30°

Instructions For Use:

  • To open the case, hold the case and make sure that “Sunlight” mark is up facing your right hand.
  • Using your left index finger and thumb press the case on both side marked “IIIII” then using your right index finger and thumb pull the top cover.
  • Hold firmly the pipette in the middle and gently pull it out from the base.

blastomere biopsy pipettes

Blastomere Biopsy Pipettes

Description / Use

  • SLM Blastomere Biopsy Pipettes are used to remove blastomeres and trophectoderm cells from embryos for pre-implantation genetic diagnosis(PGD).
  • There are five sizes and two series available for selection. The ‘Z’ series is flat tip while the ‘X’ series is beveled tip. Both styles are supplied with an ID in 20&#xB5m, 25&#xB5m, 30&#xB5m, 35&#xB5m, and 40&#xB5m. Size 20&#xB5m and 25&#xB5m are recommended for trophectoderm (TE) biopsy.
  • There is no shrinkage at the bending section, so less likely to damage blastomere in case it is sucked through.
  • All tipsare fire polished to reduce damage to the cell membrane.
  • They are supplied with a tip angle of 0°-45° and a tip to elbow length of 0.55mm.
Catalogue No. Tip Style Inner Diameter(&#xB5m) Tip Angle Degree
SBB-20Z-xx Flat 20∓0.2 xx-0° – 45°
SBB-25Z-xx Flat 25∓0.2 xx-0° – 45°
SBB-30Z-xx Flat 30∓0.2 xx-0° – 45°
SBB-35Z-xx Flat 35∓0.2 xx-0° – 45°
SBB-40Z-xx Flat 40∓0.2 xx-0° – 45°
SBB-20X-xx Beveled 20∓0.2 xx-0° – 45°
SBB-25X-xx Beveled 25∓0.2 xx-0° – 45°
SBB-30X-xx Beveled 30∓0.2 xx-0° – 45°
SBB-35X-xx Beveled 35∓0.2 xx-0° – 45°
SBB-40X-xx Beveled 40∓0.2 xx-0° – 45°

polar body biopsy pipettes

Polar Body Biopsy Pipettes

Description / Use

  • SLM Polar Body Biopsy Pipettes are used to remove polar bodies from human oocytes and embryos for pre-implantation genetic diagnosis(PGD).
  • There are three series of pipettes available for selection: 15z (flat tip), 15x (beveled tip) and 15s (spiked tip).
  • All these pipettes are designed with a fire polished edge to avoid damage to the cell membrane.
  • They are supplied with a tip angle of 0° – 45° and a tip to elbow length of 0.55mm.
Catalogue No. Inner Diameter(µm) Tip Style Tip Angle Degree
SPB-15Z-xx 13-15 Flat 20°, 25°, 30°, 35°
SPB-15X-xx 13-15 Beveled 20°, 25°, 30°, 35°
SPB-15S-xx 13-15 Beveled & Spiked 20°, 25°, 30°, 35°

zona drilling pipettes

Zona Drilling Pipettes

Description / Use

  • SLM Zona Drilling Pipettes are used to apply acidic solution for creating a hole on the zona pellucida to enable assisted hatching and/or embryo biopsy.
  • There are two sizes available for selection:ID8-10µm and ID:10-12µm. These pipettes are designed with a slightly fire polished tip.
  • They are supplied with 0° -45° tip angle and a tip to elbow lenght of 0.55mm.
Catalogue No. Inner Diameter(µm) Tip Style Tip Angle Degree
SZD-10-xx 8-10 Flat 20°, 25°, 30°, 35°
SZD-12-xx 10-12 Flat 20°, 25°, 30°, 35°

holding pipettes

Holding Pipettes

Description / Use

  • SLM Holding Pipettes are used to hold an oocyte or embryo in position during ICSI and other micro-manipulation procedures.
  • There are three series and six sizes for selection. The classic series has an ID 15-20µm and OD in 90µm, 100µm,120µm and 130µm. The ‘S’ series has smaller ID(10-15µm). The ‘B’ series has an ID 25-30µm and OD in 120µm, 130µm and 1180µm. The ‘B’ series may by used for holding an oocyte with cumulus cells attached and for embryo biopsy.
  • All our holding pipettes are supplied with a tip angle of 0° to 45° and a tip elbow length of 0.65mm.
  • Packed in a box of 10.

Ordering Information

Catalogue No. Outer Diameter(µm) Inner Diameter(µm) Tip Angle Degree
SHP-70S-xx 70∓5 10-15 xx-0° to 45°
SHP-90-xx 90∓5 15-20 xx-0° to 45°
SHP-100-xx 100∓5 15-20 xx-0° to 45°
SHP-120-xx 120∓5 15-20 xx-0° to 45°
SHP-120B-xx 120∓5 25-30 xx-0° to 45°
SHP-130-xx 130∓5 15-20 xx-0° to 45°
SHP-130B-xx 130∓5 25-30 xx-0° to 45°
SHP-180B-xx 175∓5 25-30 xx-0° to 45°

icsi tools

ICSI Injection Pipettes

Description / Use

  • SLM ICSI Injection Pipettes are used to perform intracytoplasmic sperm injection (ICSI).
  • SLM offers three types of spiked and two types of non-spiked ICSI INJECTION PIPETTES.
  • SLM offers three sizes of ICSI Injection Pipette.
  • All our injection pipettes are supplied with an angle of 0° – 45° and a tip to elbow length of 0.55 mm and 1.0 mm.
Catalogue No. Size Tip Style Tip to Elbow Length Tip Angle Degree
SIC-45V-xx
SIC-45V-xxL
SIC-45W-xx
SIC-45W-xxL
SIC-45H-xx
ID:4.0-4.5µm
OD:5-6µm
Spiked tip xx-0.55mm
xxL-1.0mm
xx-0° to 45°
SIC-45T-xx
SIC-45T-xxL
SIC-45N-xx
SIC-45N-xxL
ID:4.0-4.5µm
OD:5-µm
Non Spiked tip xx-0.55mm
xxL-1.0mm
xx-0° to 45°
SIC-50V-xx
SIC-50V-xxL
SIC-50W-xx
SIC-50W-xxL
SIC-50H-xx
ID:4.5-5.0µm
OD:6-7µm
Spiked tip xx-0.55mm
xxL-1.0mm
xx-0° to 45°
SIC-55V-xx
SIC-55V-xxL
SIC-55W-xx
SIC-55W-xxL
SIC-55H-xx
ID:5.0-5.5µm
OD:6-7µm
Spiked tip xx-0.55mm
xxL-1.0mm
xx-0° to 45°